

DNC
DNC Inherent Flame Retardant PPE2 Segmented Tape Rain Jacket 3467

- Fully seam sealed, HRC2 - ATPV: 8+cal/cm2
- 2 way radio loops on front shoulders, storm flap at centre front with SBS 7# Vislon
- 2 way heavy duty zipper/plastic slider; detachable zip off hood with SBS 5# Vislon zipper
- Elastic cuffs with adjustable sleeve tab and touch tape closure
- Twin waist pockets with flap and touch tape closure
- Hoop Pattern Bio-Motion "ANS UL-209 FR" Segmented FR Reflective Tape (50 Washes) on body and sleeves
- 2 Tone front only
Material
- 280gsm "3 layers bonded into 1" waterproof and breathable fabric
- 99% polyester and 1% anti-static carbon outer laminated to 50% Modacrylic & 60% cotton inner (soft and comfortable against skin)
Sun Protection 50+
DNC garments are tested for UPF (Ultraviolet Protection Factor) in accordance with AS/ANZS4399:2017. The level of protection varies depending on the fabric and colour of the garment. 50+ Excellent Protection.
Carbon Grid Anti-Static
The latest technology is used in the production of DNC Flame Resistant and carbon grid Anti-Static 98% Polyester/PU, 2% Carbon, breathable waterproof fabric rain jacket, vest and pants, comply with EN ISO 14116:2008 for FR & BS EN1149-5:2008 for Anti-Static. DNC cotton garments containing no metal buttons/zip are also classified under Anti-Static garments.
Electrical Protection
DNC cotton made garments containing no metal buttons or zippers and are suitable for use in electrical or gas trades.
Waterproof & Breathable
DNC HiVis Rainwear utilises the latest fabric technology. Not only are they waterproof, but also fully breathable.
HiVis D/N Fabric & Design New AS/NZS 4602.1:2011
DNC HiVis garments are standard Class F AS/NZS1906,4:2010, Class D/N, AS/NZS 4602112011 to meet the requirements of Hi-Vis Safety standards HiVis Fabric & Design of garments, for day and night use.
Hi-Vis Day Fabric Design New AS/NZS 4602.1:2011
DNC HiVis garments are manufactured to comply with New HI Vis standard Class F AS/NZS1906.4:2010, Class D AS/NZS 4602.1:2011 to meet the requirements of Hi-Vis safety standards for both HiVis Fabric & Design of garments, (Section 6.4) day use.
NENS09:2014
NFPA 70E / ATSM F1959 - Electrical Safety in the Workplace - Personal Protective Equipment (PPE) Category 1, PPE1 (HRC1)min ATPV Cal/cm2 Selected by Energy Networks Australia, use and maintenance of Personal Protective Equipment (PPE) used to protect people against electrical arc hazards within the Electrical Supply Industry. The recommended minimum ATPV for base garments is PPE (HRC 1) -- 4cal/cm, and all opening/buttons/press studs/ zippers are covered by FR Fabric.
PPE2 ATPV: 8+ Cal/cm²
NFPA 70E / ATSM F1959 - Safety in the Workplace - Personal Protective Equipment (PPE) Category 2, PPE2(HRC2)min ATPV 8 Cal/cm² .
ISO 14116:2015 (FR)
Specifies the performance requirements for the limited flame spread properties of all material assemblies and protective clothing to reduce the possibility of the clothing burning when in occasional and brief contact with small flames and constituting a hazard.
ISO 11612:2015 (FR)
The clothing is intended to protect the wearer against small splashes of molten metal, short contact with flames, radiant heat from electrical arcs, protection for welding and allied processes. It can minimize the possibility of electrical shock by short-term, contact with live electrical conductors up to approximately 100 VDC (sweat, soiling or other contaminants can affect protection levels).
Orders on all products in stock placed before 3:00 PM will ship the same business day and orders placed after 3:00 PM will ship the following business day.
At URSafeRite, customer satisfaction is our priority.