DNC Inherent Flame Retardant Lightweight PPE1 2 Tone D/N 3445
DNC Inherent Flame Retardant Lightweight PPE1 2 Tone D/N 3445
DNC Inherent Flame Retardant Lightweight PPE1 2 Tone D/N 3445
DNC Inherent Flame Retardant Lightweight PPE1 2 Tone D/N 3445
DNC Inherent Flame Retardant Lightweight PPE1 2 Tone D/N 3445
DNC Inherent Flame Retardant Lightweight PPE1 2 Tone D/N 3445

DNC

DNC Inherent Flame Retardant Lightweight PPE1 2 Tone D/N 3445

Sale price$179.00AUD
inc GST
SKU: 3445YN-XS
Color:Yellow/Navy
Size:XS
Quantity:
Leaves warehouse in 2-3 days
Details Items that are in stock can ship same day, others are sent via our partner brands. If you order products with different shipping times, we will send them all in one order which should take 5 to 7 days to ship.
Estimated shipping time above
Buy now pay later available with

Size Guide - DNC Workwear Jackets

Cotton Jacket
Size
1/2 Chest (cm)
Body Length (cm)
XS 56.5 74
S 59 75
M 61.5 76
L 64 77
XL 66.5 78
2XL 69 79
3XL 71.5 80
4XL 74 81
5XL 76.5 82
6XL 79 83

 

Cotton Bomb Jacket
Size
1/2 Chest (cm) Body Length (cm)
S 58 66
M 60.5 67.5
L 63 69
XL 65.5 70.5
2XL 68 72
3XL 70.5 73.5
4XL 73 75
5XL 75.5 76.5
6XL 78 78.5

 

Bluey Jacket
Size
1/2 Chest (cm) Body Length (cm)
S 58 71
M 60.5 72
L 63 73
XL 65.5 74
2XL 68 75
3XL 70.5 76
4XL 73 77
5XL 75.5 78
6XL 78 79
7XL 80.5 80

Size Guide - DNC Workwear Jackets

Cotton Jacket
Size
1/2 Chest (cm)
Body Length (cm)
XS 56.5 74
S 59 75
M 61.5 76
L 64 77
XL 66.5 78
2XL 69 79
3XL 71.5 80
4XL 74 81
5XL 76.5 82
6XL 79 83

 

Cotton Bomb Jacket
Size
1/2 Chest (cm) Body Length (cm)
S 58 66
M 60.5 67.5
L 63 69
XL 65.5 70.5
2XL 68 72
3XL 70.5 73.5
4XL 73 75
5XL 75.5 76.5
6XL 78 78.5

 

Bluey Jacket
Size
1/2 Chest (cm) Body Length (cm)
S 58 71
M 60.5 72
L 63 73
XL 65.5 74
2XL 68 75
3XL 70.5 76
4XL 73 77
5XL 75.5 78
6XL 78 79
7XL 80.5 80
  • 2 tone front & back, open front with FR nylon press studs & concealed snap closure
  • Gusset sleeves, under arm & upper back FR mesh venting
  • Twin chest shaped flap pockets with FR Nylon press studs
  • 2 piece structured collar
  • 2 way radio loops
  • FR thread
  • FR printed outer label
  • No metal components.
  • Double FR stitching, standard hoop pattern LOXY Sto-nor 9801
  • FR Reflective Tape
Material
  • 180gsm supa soft & cool
  • 61% Modacrylic, 30% Cotton, 5% Para-aramid, 3% Lyocell, 1% Anti-static Inherent FR Fabric

 Sun Protection 50+

DNC garments are tested for UPF (Ultraviolet Protection Factor) in accordance with AS/ANZS4399:2017. The level of protection varies depending on the fabric and colour of the garment. 50+ Excellent Protection.

 Carbon Grid Anti-Static

The latest technology is used in the production of DNC Flame Resistant and carbon grid Anti-Static 98% Polyester/PU, 2% Carbon, breathable waterproof fabric rain jacket, vest and pants, comply with EN ISO 14116:2008 for FR & BS EN1149-5:2008 for Anti-Static. DNC cotton garments containing no metal buttons/zip are also classified under Anti-Static garments.

Hi-Vis Day Fabric Design New AS/NZS 4602.1:2011

DNC HiVis garments are manufactured to comply with New HI Vis standard Class F AS/NZS1906.4:2010, Class D AS/NZS 4602.1:2011 to meet the requirements of Hi-Vis safety standards for both HiVis Fabric & Design of garments, (Section 6.4) day use.

 Hi-Vis Day/Night Fabric Design New AS/NZS 4602.1:2011

DNC HiVis garments are manufactured to comply with New Hi Vis standard Class F AS/NZS1906.4:2010, Class D/N, AS/NZS 4602.1:2011 to meet the requirements of Hi-Vis safety standards HiVis Fabric & Design of garments, for day and night use.

 Flame Retardant

DNC Patron Saint® flame retardant range complies with Class EN ISO11612. Also EEC Standards, EN470-1, EN531.

 ISO 14116:2015 (FR)

Specifies the performance requirements for the limited flame spread properties of all material assemblies and protective clothing to reduce the possibility of the clothing burning when in occasional and brief contact with small flames and constituting a hazard.

ISO_FR_141_Symbols-60 ISO 11612:2015 (FR)

The clothing is intended to protect the wearer against small splashes of molten metal, short contact with flames, radiant heat from electrical arcs, protection for welding and allied processes. It can minimize the possibility of electrical shock by short-term, contact with live electrical conductors up to approximately 100 VDC (sweat, soiling or other contaminants can affect protection levels).

 NENS09:2014

NFPA 70E / ATSM F1959 - Electrical Safety in the Workplace - Personal Protective Equipment (PPE) Category 1, PPE1 (HRC1)min ATPV Cal/cm2 Selected by Energy Networks Australia, use and maintenance of Personal Protective Equipment (PPE) used to protect people against electrical arc hazards within the Electrical Supply Industry. The recommended minimum ATPV for base garments is PPE (HRC 1) -- 4cal/cm, and all opening/buttons/press studs/ zippers are covered by FR Fabric.

PPE1 PPE1 ATPV: 4+ Cal/cm²

NFPA 70E / ATSM F1959 - Electrical Safety in the Workplace - Personal Protective Equipment (PPE) Category 1, PPEl(HRCl)min ATPV Cal/cm².

 Environmentally Friendly Green Dye Oeko-Tex Standard 100

All DNC garments use the Green Dye only, except for the Patrol Saint Flame Retardant range. AlI DNC garment fabric fully complies with Oeko-Tex standard 100 class II for products with direct contact to the skin in which prohibited to use aromatic amines, sensitizing dyes and cancer risk dyes. Green dye should meet the following conditions: Does not contain harmful or non-aromatic amine; dye itself, non-carcinogenic, sensitization, acute toxicity; the use of formaldehyde and, after extraction of heavy metals in the following limits; non-environmental hormone; non persistent organic pollutants; does not produce pollution of the environment harmful chemicals; not produce chemicals that pollute the environment; colour fastness and superior to disable the use of dyes.

 LOXY 9801 FR R.Tape

DNC use the premium LOXY Sto-nor 9801 Flame Resistant (FR) Reflective Tape through our Flame Resistant Range, LOXY Sto-nor 9801 FR tape. Industrial washes 50 cycles @60°C, complies with ISO14116/FR, NFPA2112 /FR; EN 1149-3/Anti-Static, AS/NZS1906.4/Hi-Vis.

DNC Cool-Breeze airflow cooling system removes sweat and body heat throughinnovative under-arm vents, upper back or vertical vents. Cool-Breeze Airflow Vents

DNC Cool-Breeze airflow cooling system removes sweat and body heat through Innovative under-arm vents, upper back or vertical vents.

Customer Reviews